Home

How the EPC C checker works

Last reviewed 28 October 2026

The checker gives an estimate. It is not an EPC, which only an accredited assessor can produce after visiting the property. This page explains every step and where each figure comes from, so you can judge the result for yourself.

1. The rules it checks against

In January 2026 the government confirmed that privately rented homes in England and Wales must reach EPC C, or a registered exemption, by 1 October 2030 (government response). The checker uses these confirmed points:

2. The starting score

The best starting point is the score on the property's current EPC, which anyone can look up free on the government EPC register. If you only know the letter, the checker uses the middle of that band. If you don't know either, it makes a rough estimate from your answers about the property, and says so clearly in the result.

3. Turning upgrades into points

An EPC score isn't a simple tally of features. It comes from the home's modelled energy cost per square metre of floor area, called the energy cost factor (ECF). The SAP methodology behind every EPC converts the ECF into a score with two published equations (source):

If ECF is 3.5 or more:   score = 117 - 121 x log10(ECF)
If ECF is under 3.5:     score = 100 - 13.95 x ECF

The checker runs those equations in reverse to get the ECF from your current score. Each upgrade then cuts the modelled energy cost by a typical percentage, and the new ECF is turned back into a score. This matters for two reasons:

Each step shows a range, from 70% to 130% of the typical cut, because real results depend on the property.

The typical cut for each upgrade

These percentages are an accredited assessor's judgement of typical results, informed by published savings figures. They aren't from a single official table, so treat them as estimates.

UpgradeTypical cost cutPoints from D61Points from E45
Loft insulation to 270mm (from bare)20%+8+11
Loft insulation top-up to 270mm (from under 100mm)7%+3+4
Loft insulation top-up to 270mm (from 100 to 200mm)2.5%+1+1
Cavity wall insulation18%+7+10
Internal solid wall insulation22%+9+12
Suspended timber floor insulation5%+2+3
Replace single glazing with A-rated double glazing7%+3+4
New A-rated condensing gas boiler18%+7+10
Modern high heat retention storage heaters25%+10+14
Replace panel heaters with high heat retention storage heaters40%+16+22
Full heating controls (programmer, room stat, TRVs)8%+3+4
Complete heating controls3%+1+2
Hot water tank jacket and pipe lagging3%+1+2
Low energy (LED) bulbs throughout3%+1+2
Swap remaining bulbs to LED1.2%+0+1
Solar panels (about 3.5kWp)22%+9+12

4. Choosing the cheapest route

The checker only considers upgrades that apply to the property, based on your answers. At each step it picks the upgrade with the lowest cost per point from where the home is at that moment, until the typical result reaches 69. Anything else that could help is listed separately.

Where you answered "not sure", the checker fills the gap from the property's age. For example, it assumes a 1950s house has unfilled cavity walls. Upgrades that depend on a guess like this are tagged "check first" in the result.

5. Where the costs come from

UpgradeSource
Loft and cavity wall insulationEnergy Saving Trust figures, via Rightmove and HomeOwners Alliance
Solid wall insulationEnergy Saving Trust (about £12,000 internal, £18,000 external, for a typical semi)
Suspended floor insulationEnergy Saving Trust (£1,400 to £2,500)
Double glazingEnergy Saving Trust figure, via EcoWatch
Boiler replacementEnergy Saving Trust figure, via Rightmove
Solar panelsWhich?, citing Energy Saving Trust
Heating controls, storage heaters, tank jackets, LED bulbs, loft top-upsEstimates. No single published source. Marked "estimate" in the results.

Costs for solid wall insulation and glazing are published for a typical semi-detached house. For other property types, the checker scales them by a size factor (flat 0.45, mid-terrace 0.65, semi 1, detached 1.5, bungalow 0.9). All costs are before grants.

6. Bills before and after the upgrades

The checker already works out how much the chosen upgrades cut the home's modelled energy cost (step 3). It applies that same percentage cut to the part of the bill that goes on heating and hot water.

Heating and hot water = bill - standing charges - appliances, lighting and cooking
Saving = that amount x (1 - modelled cost after / modelled cost before)

Treat the result as a guide. EPC savings assume a standard household heating the home to a standard temperature. Many homes, especially poorly insulated ones, are kept cooler than that, so real savings are often smaller. Some of the benefit then shows up as a warmer home rather than a lower bill.

Upgrades don't change what appliances cost to run. To see those, use the appliance running costs.

7. What the checker can't do